Pages

09 March, 2024

SNMP OID not supported in HP GEN11 but same supported in old HP GEN machines

In DL325 GEN11 DA most of the SNMP OID below returns no such oid available for GEN11 but same works and returns the value in GEN10/GEN10 Plus. What to do get those values ?




cpqSeCpuStatus :
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.1.2.2.1.1.6
SNMPv2-SMI::enterprises.232.1.2.2.1.1.6 = No Such Instance currently exists at this OID
cpqDaCntlrCondition :
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.2.1.1.6
SNMPv2-SMI::enterprises.232.3.2.2.1.1.6 = No Such Instance currently exists at this OID
cpqDaAccelCondition :
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.2.2.1.9
SNMPv2-SMI::enterprises.232.3.2.2.2.1.9 = No Such Instance currently exists at this OID
cpqDaLogDrvStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.3.1.1.4
SNMPv2-SMI::enterprises.232.3.2.3.1.1.4 = No Such Instance currently exists at this OID
cpqDaLogDrvCondition :
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.3.1.1.11
SNMPv2-SMI::enterprises.232.3.2.3.1.1.11 = No Such Instance currently exists at this OID
cpqDaPhyDrvStatus :
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.5.1.1.6
SNMPv2-SMI::enterprises.232.3.2.5.1.1.6 = No Such Instance currently exists at this OID
cpqDaPhyDrvCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.5.1.1.37
SNMPv2-SMI::enterprises.232.3.2.5.1.1.37 = No Such Instance currently exists at this OID
cpqDaPhyDrvSmartStatus :
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.5.1.1.57
SNMPv2-SMI::enterprises.232.3.2.5.1.1.57 = No Such Instance currently exists at this OID
cpqDaTapeDrvStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.3.2.9.1.1.8
SNMPv2-SMI::enterprises.232.3.2.9.1.1.8 = No Such Instance currently exists at this OID
cpqHeEventLogCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.11.2.0
SNMPv2-SMI::enterprises.232.6.2.11.2.0 = No Such Instance currently exists at this OID
cpqHeThermalSystemFanStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.6.4
SNMPv2-SMI::enterprises.232.6.2.6.4 = No Such Instance currently exists at this OID
cpqHeThermalCpuFanStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.6.5
SNMPv2-SMI::enterprises.232.6.2.6.5 = No Such Instance currently exists at this OID
cpqHeFltTolFanCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.6.7.1.9
SNMPv2-SMI::enterprises.232.6.2.6.7.1.9 = No Such Instance currently exists at this OID
cpqHeTemperatureCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.6.8.1.6
SNMPv2-SMI::enterprises.232.6.2.6.8.1.6 = No Such Instance currently exists at this OID
cpqHeFltTolPwrSupplyCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.9.1
SNMPv2-SMI::enterprises.232.6.2.9.1 = No Such Instance currently exists at this OID
cpqHeFltTolPowerSupplyCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.9.3.1.4
SNMPv2-SMI::enterprises.232.6.2.9.3.1.4 = No Such Instance currently exists at this OID
cpqRackCommonEnclosureFanCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.22.2.3.1.3.1.11
SNMPv2-SMI::enterprises.232.22.2.3.1.3.1.11 = No Such Instance currently exists at this OID


cpqRackPowerSupplyCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.22.2.5.1.1.1.17
SNMPv2-SMI::enterprises.232.22.2.5.1.1.1.17 = No Such Instance currently exists at this OID
cpqHeResilientMemCondition:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.6.2.14.4
SNMPv2-SMI::enterprises.232.6.2.14.4 = No Such Instance currently exists at this OID
cpqNicIfLogMapStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.18.2.2.1.1.11
SNMPv2-SMI::enterprises.232.18.2.2.1.1.11 = No Such Instance currently exists at this OID
cpqFcaHostCntlrStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.16.2.7.1.1.4
SNMPv2-SMI::enterprises.232.16.2.7.1.1.4 = No Such Instance currently exists at this OID
cpqNicIfPhysAdapterStatus:
~# snmpwalk -v2c -c 7810_ext localhost 1.3.6.1.4.1.232.18.2.3.1.1.14
SNMPv2-SMI::enterprises.232.18.2.3.1.1.14 = No Such Instance currently exists at this OID

No comments:

Post a Comment

Thanks